WHAT IS IT?
Focused Heat System
A focused defrosting system for walk-in freezers.

The Problem
Ice builds up on the refrigerant distribution (spider) valves in walk-in freezers. It’s a common cause of refrigerant line failure and door damage, and it costs businesses money in repairs and lost product.
The Solution
An add-on heating system that defrosts the distribution valve, eliminating ice build-up and preventing fractures.
The Pay-Off
Used in many warehouse clubs and grocery stores across the nation, helping them operate with confidence and avoid costly repairs and lost product.
MODELS
Expansion Valve Heater Kits
| EMH20-48 | EMH10-20 | |
|---|---|---|
| Wattage | 1000 W | 500 W |
| Voltage | 480 V | 208 V |
| Heated length | 20 in. | 10 in. |
| Element temperature | 700 °F | 700 °F |
| Thermostat opens at | 150 °F | 150 °F |
| Enclosure | NEMA 4, steel | NEMA 4, steel |
| Additional circuit load | ≈2 A | ≈2 A |
In the kit
Custom-formed tubular heating element · molded high-limit thermostat · NEMA 4 steel electrical junction box · heater power supply cable · fuse holder.
How it installs
The heating element mounts through the compartment wall next to the distributor tubes. The thermostat bulb secures to the expansion valve. Power comes from the unit’s defrost cycle circuit through the supplied fuse block. Instructions come with every kit.